GW Instek PEL-5005G-600-350 - PEL-5000G Series High Power Turbo (600V, 525A, 7.5kW)
GW Instek PEL-5000G series single-channel electronic load provides 150V/ 600V/ 1200V models with a power range of 4kW~6kW. PEL-5000G has a total of 9 models featuring different combinations of power, voltage, and current. It can test and verify the specifications of batteries, electric vehicle chargers/charging stations and electric vehicle batteries. PEL-5000G supports parallel connection for same voltage specification and different power models. PEL-5000G can support up to 8 units connected in parallel to provide a maximum power of 48kW.
For the scenario of Battery Charger testing, PEL-5000G specifically provides four battery discharge modes, namely CV+Current Limit test mode, CV+Power Limit test mode, CC mode and CP mode. Users can choose a suitable test mode according to the test requirements.
For Battery Discharge Function, users can set the discharge cut-off voltage, discharge time, or discharge capacity (Ah) in CC or CP mode to meet the battery testing requirements.
In order to meet the verification requirements of different DUTs, PEL-5000G provides a variety of test functions, Surge current test mode, automated OCP, OPP test functions and 150 sets of parameter storage function. The 1200V model of PEL-5000G not only provides full power output at 1000V, but also provides 60% power output at 1200V output, which is higher than the 50% power output of other manufacturers of similar electronic loads.
High-voltage batteries or chargers directly connected to the electronic load may cause damage to the electronic load. PEL-5000G has a built-in slow starter, which not only protects the DC load, but also saves the user's installation cost and setting time for measurement on 600V/1200V models.
The communication interfaces supported by PEL-5000G include GPIB, RS232, USB, and LAN. The power, voltage and current of each model are shown in the following table:
|
Power / Voltage |
150V |
600V |
1200V |
|||
|
4kW |
PEL-5004G-150-400 |
(400A) |
PEL-5004G-600-280 |
(280A) |
PEL-5004G-1200-160 |
(160A) |
|
5kW |
PEL-5005G-150-500 |
(500A) |
PEL-5005G-600-350 |
(350A) |
PEL-5005G-1200-200 |
(200A) |
|
6kW |
PEL-5006G-150-600 |
(600A) |
PEL-5006G-600-420 |
(420A) |
PEL-5006G-1200-240 |
(240A) |
- 5 digital V / A / W Meter can be displayed on Large LCD display simultaneously
- Flexible CC, CR, CV, CP, CV + CL, CV + PL, Dynamic and short circuit operation modes
- Not only CC, CR, and CP mode have parallel operation functions, but CV mode also has parallel operation functions
- Surge Test mode for Capacitive load for current rising transient test
- Voltage meter display can be configured as polarity positive (“+”) or negative (“-”)
- Master-slave control is up to 1 Master and 7 Slaves
- Optional Interface: GPIB, RS232, USB, LAN
- SEQ Load Mode's programmable function allows for ultra-high-speed step changes from 0.02 to 999000 ms in CC or CP mode
- Provide battery BMS protection test function
- Optional 9923 load current waveform generator to provide the battery actual discharge current waveform simulation
- Built-in test modes include Battery Discharge, BMS, Short circuit, OCP, OPP test modes
- Turbo mode can withstand up to 1.5 times the current and power electronic load within 2 sec. period, most fit BMS, Short circuit, OCP, OPP test
- Protection against V, I, W, and ℃
Turbo Mode
| Specs |
| ||||||||||||||||||||||||||
| Protections |
| ||||||||||||||||||||||||||
| Constant Current Mode |
| ||||||||||||||||||||||||||
| Constant Resistance Mode |
| ||||||||||||||||||||||||||
| Constant Voltage Mode |
| ||||||||||||||||||||||||||
| Constant Power Mode |
| ||||||||||||||||||||||||||
| Constant Voltage Mode + Current Limit Mode |
| ||||||||||||||||||||||||||
| Constant Voltage Mode + Power Limit Mode |
| ||||||||||||||||||||||||||
| Short / OCP / OPP Test Function |
| ||||||||||||||||||||||||||
| BMS Test Mode*7 |
| ||||||||||||||||||||||||||
| Surge Test Mode |
| ||||||||||||||||||||||||||
| Batt Test Mode |
| ||||||||||||||||||||||||||
| SEQ Load Mode (remode only) |
| ||||||||||||||||||||||||||
| Dynamic Mode |
| ||||||||||||||||||||||||||
| Conf Key Parameter |
| ||||||||||||||||||||||||||
| Measurement |
| ||||||||||||||||||||||||||
General
| Typical Short Resistance | 28.584mΩ |
| Maximum Short Current | 350A |
| Load ON Voltage | 0.4 ~ 100V |
| Load OFF Voltage | 0 ~ 99.6V |
| Power Consumption | 550VA |
| Dimension(H x W x D) | 177mm x 440mm x 745mm |
| Weight | 29kg |
| Temperature*8 | 0 ~ 40°C |
| Safety & EMC | CE |
Note *1: The power rating specifications at ambient temperature -25°C
Note *2: The range is automatically or forcing to range II only in CC mode
Note *3: If the operating current is below range 0.1%, the accuracy specification is 0.1% F.S.
Note *4: Power range = Vrange x Irange
Note *5: Turbo mode for up to 1.5x Current rating & Power rating support Surge, Bms, Short / OCP / OPP test function
Note *6: The best accuracy of OCP / OPP test is Istep / Pstep = 1%FS
Note *7: BMS Test function for Battery Management System Board SHORT, OCCP and OCDP Test
Note *8: Operating temperature range is 0~40 °C, All specifications apply for 25 °C±5 °C, Except as noted
Do you have a PEL-5000G Series High Power Turbo (600V, 525A, 7.5kW) that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your PEL-5000G Series High Power Turbo (600V, 525A, 7.5kW) calibrated today! Click Here!
There are currently no reviews for this product.
Recommended Accessories for the PEL-5000G Series High Power Turbo (600V, 525A, 7.5kW)
![]()
GPIB & RS-232 Card for AEL-5000C Series
![]()
9923 RS232 interface
![]()
GPIB Card for PEL/AEL-5000C Series