Your Cart
(empty)
0
Tradeport Electronics
measurement is our business
Cart : (empty)

Introduction-GLC-10000: Leakage Current Tester (Up to 50mA)



GW Instek launches a new leakage current tester – GLC-10000, which features 12 simulated human impedance networks that comply with related safety regulations to conduct leakage current test for electric equipment under normal condition or single fault condition. These 12 simulated human impedance networks are comprised of networks for medical electric equipment and general electric and electronic equipment to ensure that the product design and manufacture are in compliance with requirements of safety regulations including IEC, EN, UL, etc.

GLC-10000 provides test requirements for most IT products, household appliances and other electronic and electric equipment, and even medical electronics in the measurement of leakage current (or touch current), including the required measurement network, measurement bandwidth of various current forms are all in compliance with the requirements of the latest version of the applicable regulations. Furthermore, in order to comply with the leakage current flow paths under different regulations, GLC-10000 provides 20 measurement options to meet the requirements of the old and latest versions of the standards.

  GLC-10000 (NEW) GLC-9000 (OLD)
Outlook
Display 7" TFT LCD 5.7" TFT LCD
Operation Touch (Capacitive) Touch (Resistive)
Selectable MD 12 9
DC
Range 50µA/500µA/5mA/50mA 50µA/500µA/5mA/25mA
Resolution 0.01µA/0.1µA/1µA/10µA 0.01µA/0.1µA/1µA/10µA
Accuracy ±2.0% fs/±(0.2% rdg+6dgt) ±1.0% fs/±(0.2% rdg+3dgt)
AC / AC+DC
Range 50µA/500µA/5mA/50mA 50µA/500µA/5mA/25mA
Resolution 0.01µA/0.1µA/1µA/10µA 0.01µA/0.1µA/1µA/10µA
Accuracy -- 0.1Hz<f≤15Hz 4.0% fs/±(4.0% rdg+10dgt)  ×
Accuracy -- 015Hz<f≤100kHz 2.0% fs/±(2.0% rdg+6dgt) 2.0% fs/±(2.0% rdg+6dgt)
Accuracy -- 100kHz<f≤1MHz 2.0% fs/±(2.0% rdg+10dgt) 2.0% fs/±(2.0% rdg+10dgt)
AC Peak
Range 750µA/7.5mA/75mA 500µA/1mA/10mA/75mA
Resolution 1µA/10µA/100µA 0.1µA/1µA/10µA/100µA
Accuracy -- 15Hz<f≤10kHz 4.0% fs/±2.5%/±(2.0% rdg+6dgt) ±5.0% fs/±(5.0% rdg+10dgt)
Accuracy -- 10kHz<f≤100kHz 5%fs/±5%fs/±5%fs ×
Accuracy -- 100kHz<f≤1MHz 15.0%fs/±15.0%fs/±20.0%fs ×
Others
EUT (V/I Check) 85V ~ 300V / 0.5A ~ 20A 85V ~ 300V / 0.5A ~ 10A
EUT Breaker Yes Yes
EUT Rated Current (max.) Front: 10A / Rear: 20A Front: 10A / ×
Measured Data Storage 1000 Sets 50 Sets
MD OUT terminal Yes ×
EXT MD terminal Yes ×
Interface RS-232C, USB host & device, LAN, Signal I/O, GPIB(opt.) RS-232C, USB host & device, Signal I/O, GPIB
Power Source (for GLC) AC 100V~240V±10% AC 100V/120V/2220V/230V±10%
(for EUT) AC 100V~240V±10% AC 85V ~ 250V, 50/60Hz
Power Consumpution 50VA (max.) 30VA (max.)
Dimension(WxHxD), mm  342 × 133.87 × 348.51 330 × 150 × 350
Weight 7.8 kg 5 kg

 

Key Features

  • Suitable for Medical Electrical & General Electrical of Leakage Current Measurement
  • 7’ Touch Pane with Color LCD
  • 12 Different Measurement Network to Simulate the Resistance of Human Body (including IEC 60601-1:2020 3.2rd)
  • The Measurement of Maximum Allowable Leakage Current is Up to 50mA
  • External Terminal for Extension MD Connection
  • MD OUT Terminal can be Connected to an Oscilloscope for Convenient Comparison of Measured Waveforms
  • 30 Sets Memories for Test Parameter; 1000 Sets Memories for Measured Data.
  • Test Parameter Export/Import Function through USB Host
  • USB Storage for Measurement Data/ Screen Capture
  • Various Standard Interfaces: RS-232C, USB Host & Device, LAN, Signal I/O and GPIB (optional)

 

GLC-10000 - Leakage Current Tester

Up to 50mA Leakage Current Tester, features 12 simulated human impedance networks, 20 measurement options and more.

$3,855 (USD)

Up to 50mA Leakage Current Tester, features 12 simulated human impedance networks, 20 meas...

View Product